Cords




BRAIDED CARBON CORD

ACP's braided carbon cord is manufactured from high strength carbon fibers and is braided in two sizes, .025" diameterand .034" diameter. It can be used as a jointwrap in most areas where nylon string orthin wire was used to wrap and bind parts together. After the wrap is complete, saturate with CA adhesive to produce a much lighter and stronger joint. Use to reinforce around the inside and outside of compound curves to strengthen comer joints or inlay in the edge of fommers to stiffen them.

BRAIDED Kevlar® CORD

Braided Kevlar® Cord is a .025" diameter, eight strand, tightly woven braided Kevlar®, which can be used for wrapping center wing sparjoints, carbonfibersparcaps, andthe leading edgeofcombat models.

KEV-CORD

Kev-Cord is composed of an eight strand braided Kevlar® filament inner core surrounded with a high density vinyl jacket. This combination provides a control linkage that will not stretch and is protected from fraying by the vinyi coating. It is ideal for any application that requires a precise pull-cord actuator. Kev-Cord may be used with pulleys, threaded through guide tubes and used in tension unsupported. Each pack comes with four sleeves specifically sized for either the .038 or the .058 to be used for crimping a loop for attachment of the cable to a control horn.

Construction Hint:

For pull cables, the following cable rigging is recommended: At the surface, the cable termination can be accomplished by passing the Kev-Cord through the hole originally intended for the rod, putting an eight knot on the end of the Kev-Cord and pulling it back through the clevice fork. At the servo end of the cable, we recommend you slip the Kev-Cord through the hole in a rigging coupler and then use the sleeve provided to crimp the loop. The clevice can then be threaded on to the rigging coupler to allow adjustment ofthe control cables. Additional sleeves are available, six per package.

KEV-CORD CONNECTOR

Two 440 threaded connectors each of which has a hole running the full length of the connector that allows the .038" KEV-CORD to pass through the connector and be knotted on the end. Secure the knot with CA glue. A clevice can be threaded on to the connector over the KEV-CORD for attachment to control horns. The connector also incorporates a hex-head that can be turned with a wrench for adjustment of the pull pull lines.

Return to Home Page
Order Form
ACP Contacts, Phone Numbers, Mailing Address
About ACP

E-mail: Info@acp-composites.com